Реле безопасности серии MSR5T (Guard master)

Цена: 0 грн

Description

The MSR5T has 1 N.C. single channel input for use with gate interlocks and emergency stop buttons in lower risk applications.

The MSR5T has output monitoring that can accommodate an automatic/manual reset function. Automatic/manual reset can use a jumper or can be used to check operation of the contacts.

The MSR5T has 3 N.O. safety outputs and 1 N.C. auxiliary output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. The auxiliary contact is a nonsafety output intended to provide an external signal about the status of the safety outputs.

The Minotaur power supply converts either 110V AC or 230V AC to 24V DC. It is intended to be used with an MSR5T or a Ferrotek noncontact interlock. When used with the MSR5T, the Minotaur power supply acts like a 110V AC (230V AC) input module allowing a single channel 110V AC (230V AC) circuit to be wired directly into a safety circuit.


Features
 

  • Category 4 per EN 954-1
  • Stop category 0
  • Single channel input
  • Three N.O. safety outputs
  • One N.C. auxiliary output
  • 22.5 mm wide housing
  • Optional 110/230V AC input module


Applications
 

Click to enlarge - 440R-B23020_Application


Specifications
 

Safety Ratings
Standards IEC 60204-1, ISO 13849-1, (EN 954-1)
Safety Classification Cat. 4 per EN 954-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visithttp://www.ab.com/safety/
PFHD: < 2.5 x 10-9
MTTFd: > 45662 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, TÜV, and CCC
Power Supply
Input Power Entry
Power Consumption <4V A
Inputs
Safety Inputs 1 N.C.
Encoders Supported ‡   
Input Simultaneity Infinite
Input Resistance, Max. 200 W
Reset Auto/Manual or Manual Monitored
Power ON Delay Time
Motor Voltage, Max.
Outputs
Safety Contacts §  (Immediate)  
Safety Contacts (Delayed)  
Auxiliary Contacts (Immediate)  
Auxiliary Contacts (Delayed)  
Timed Off-Delay ‡   
Timed On-Delay ‡   
Timed One Shot ‡   
Thermal CurrentIlth 10 A
Rated Impulse withstand Voltage 2500V
Rated Insulation Voltage (Ui) 500V
Switching Current @ Voltage, Min. 5 mA @ 5V DC
Contact Material
Switched Current/Voltage/Load, Min. =1,1061191
Fuses, Output (External) 5 A quick acting
Electrical Life 220V AC/4A/880VA cosf = 0.35 - 100,000 operations
220V AC/1.7A/375VA cosf = 0.6 - 500,000 operations
30V DC/2A/60W - 1,000,000 operations
10V DC/0.01A/0.1W - 2,000,000 operations
Mechanical Life 2,000,000 operations
Utilization Category
A600/AC-15 (Ue) 600V 500V 240V 120V
  (le) 1.2 A 1.4 A 3 A 6 A
N600/DC-13 (Ue) 600V 500V 250V 120V
  (le) 0.4 A 0.55 A 1.1 A 2.2 A
Operating Characteristics
Response Time
Recovery Time
Status Indicator Green = Output
Environmental
Enclosure Type Rating IP20
Terminal Protection IP20, DIN 0470
Relative Humidity 90%
Pollution Degree 3
Operating Temperature [C (F)] -20…+80° (-4…+176°)
Vibration 0.75 mm (0.30 in.) peak, 10…55 Hz
Shock 30 g, 11 ms half-sine
Installation Group C in accordance with VDE 0110
Physical Characteristics
Mounting 35 mm DIN Rail
Weight [g (lb)] 520 (1.15)
Conductor Size, Max.
Torque Settings, Max. (Terminal Screws) 1 N•m (8.85 lb•in)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 
51840 operations per year
- Mission time/Proof test interval of 20 years—actual values to be decided
- Power cycled once per 8 hrs
‡ 
§ 


Product Selection
 

Inputs Safety Outputs Auxiliary Outputs Power Supply Cat. No.
1 N.C. 3 N.O. 1 N.C. 24V AC/DC ±15% 50/60 Hz 440R-B23020
  


Accessories
 

Description Page Number Cat. No.
110/230V AC to 24V DC Power Supply Power Supply Unit 440R-A32003
  


Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
 

Click to enlarge - 440R-B23020_Dims


Block Diagram
 

Click to enlarge - 440R-B23020_Block Diagram


Typical Wiring Diagrams
 

Click to enlarge - 440R-B23020_Wiring
 

PDF /var/upload/files/Allen%20Bredley/safety%20modules/Safety%20MSR5T.pdf

Компания Hydronix – мировой лидер в сфере производства микроволнового оборудования для измерения влажности сыпучих материалов, бетонных смесей и пр.
Датчики Hydronix заслужили непревзойденную репутацию благодаря точности измерений, прочности конструкции и эксплуатационной надежности. Функциональная гибкость изделий Hydronix позволяет эффективно интегрировать их в любую...

ООО «Интеравтоматика» является официальным партнером международного концерна OEM Automatic. OEM Automatic - фирма, более сорока лет специализирующаяся на производстве и поставках компонентов промышленной автоматики и электроники, имеющая филиалы в двенадцати европейских странах. Акции OEM Automatic котируются на Стокгольмской фондовой бирже.

ООО «Интеравтоматика» является официальным дистрибьюторм фирмы Jay Electronique. Компания Jay Electronique  является производителем устройств управления и передачи информации, основанных на использовании беспроводной связи. Jay Electronique специализируется на  следующих направлениях деятельности:
микроволновая передача данных;
работа с различными...

Mafelec - производитель элементов контроля и управления топ-уровня. Ассортимент продукции исключительного качества составляют: Специальные кнопки для транспортных средств, автобусов, аэропортов, поездов, железных дорог, кнопки для панелей управления водителей, специальные индикаторные лампы.
Дисплеи для сообщений, информационные дисплеи (для вокзалов, аэропортов), иллюминационные...